The basic setting method of 2011 Audi air-conditioner heating system compressor

Actual Measurement:
Audi,2011,VIN=WAUZZZ4H2BN0*****,see as pictures.

Occur 3 fault code:
B10C811 coolant shutoff valve to ground short negative/accidental
B10C654 trial run adjustment has no basic active/static
U111300 is limited active/static due to receiving fault values

Operation Procedure:
1.Select Audi V27.67 above;
2.Select fast test;
3.Select 08 air-conditioner/heating system, see s pic2.

4.Select 10 channel adjustment match, as shown in figure 3

5.Select compressor operation and air conditioning performance test, as shown in FIG.4

6.The compressor runs and the air conditioner is completed correctly, as shown in FIG.5

7. Return to the main menu, clear the fault code, then close the key and exit the software. Restart the engine, the fault light no longer light, air conditioning work normal, explain the problem has been solved.

By Launch X431 PAD V or Launch X431 V/ launch x431 V+
https://www.autonumen.com/goods-7139-Launch-X431-PAD-V-PAD5-Full-System-Professional-Diagnostic-Tools.html